InertSustain PFPA pentafluorophenyl-modified column designed for enhanced separation of structurally similar compounds through multiple retention mechanisms, including π-π, dipole, and hydrogen bonding interactions.
InertSustain PhenylA directly bonded phenyl group gives the InertSustain Phenyl column unique reversed-phase selectivity, ideal for separating polar compounds and structural isomers via π-π and hydrogen bonding interactions.
InertSustain PhenylhexylA phenylhexyl-bonded column that offers complementary selectivity to traditional alkyl-chain columns, providing high inertness, reproducibility, and low back pressure.
LD249 Gas Leak DetectorCompact, easy-to-use leak detector with thermal conductivity sensor for fast, accurate gas detection. Replaces the LD239.
FM4: Air Sampler for PFASLow-volume air sampler for PFAS enabling comprehensive analysis of both gas and particle phases in a single sampling using stage-optimized materials.
OralChroma Halitosis Measuring DeviceHigh-precision breath analyzer using gas chromatography to quantify VSCs in 4 minutes — fast, reliable, and maintenance-free.
Inertsil columns were developed by GL Sciences in 1986 for sample separations using high-performance liquid chromatography. Starting with Inertsil ODS, a new type of bonded silica was produced providing unmatched performance and reproducibility. Further refinements of evolved silica and the introduction of new phases have allowed Inertsil to achieve industry leading performance for analyte separation to become one of the most highly used columns for HPLC. Read more
Inertsil ODS-4 delivers the same extreme inertness to any type of compounds just like InertSustain C18 along with unprecedented stability under 100 % aqueous mobile phases for qualitative and quantitative analysis. However, as the base silica gel and carbon loading are different on Inertsil ODS-4, differences in selectivity can be observed for certain analytes.
Inertsil ODS-3 is still GL Sciences’ most popular phase and continues to be used widely and reliably for long-established methods in pharmaceutical, and contract research labs. Inertsil ODS-3 columns have a relatively strong retentivity compared to commercially available ODS columns. In addition, the introduction of higher surface area silica provide high preparative loading ...
The same base silica gel and bonding technology that is used for Inertsil ODS-3 is also employed for Inertsil C8-3. The difference between the two phases is just the length of the hydrocarbon ligands. 10 μm particle size columns are also available to meet the requirement of various pharmacopeia methods. We recommend InertSustain C8 columns for all new method development.
Many chromatographers prefer a C8 column when an ODS phase shows excessive retention values. Inertsil C8-4 provides the same separation pattern (selectivity) and extreme inertness to any type of compounds just like Inertsil ODS-4, which enables easy method transfer from ODS-4 to C8-4 while other commercially available ODS and C8 columns can show dramatically different ...
Inertsil ODS-2 columns have a pore size of 150 Å offering symmetric peaks for bases, acids with low pressure. When Inertsil ODS-2 was introduced in 1987s, this HPLC transformed the entire industry. Inertsil ODS-2 was the first HPLC phase created using ultra high purity silica, which produced superior base deactivation. Inertsil ODS-2 is one of the most popular phase and ...
Inertsil CN-3, Cyanopropryl groups bonded to Silica gel with high density. And it is not only increase difference recognition of hydrophilicity, but also increase the durability. It is difficult to increase the both performance with other previous cyanopropryl columns. Inertsil CN-3 can be cleaned with 100 % aqueous solvent because non-specific adsorption of water effected ...
Just like InertSustain Phenyl, Inertsil Ph-3 has phenyl groups directly bonded to the silica gel which provides pure reverse phase characteristics that are critical to resolving highly polar compounds like acidic and basic pharmaceuticals. The near perfect phenyl phase coverage on this material results in symmetric, narrow peaks for even the most polar compounds while using ...
GL Sciences offers a polymerically bonded ODS-P phase which provide high steric selectivity for separation of planar and non-planar compounds. nertsil ODS-P columns are also ideal for the HPLC analysis of 16 PAH compounds, listed as target pollutants by the US EPA.
Inertsil ODS-EP contains a polar functional group embedded between the silica surface and the C18 group. The embedded polar group makes the C18 phase stable in 100 % aqueous eluents without "phase collapse."
This phase is also extremely "base deactivated" and provides superior peak shape for acids and bases in organic eluents as well as acidified eluents typically used in ...
Inertsil ODS-SP is super base deactivated and optimally bonded to retain hydrophilic compounds without excessive retention of hydrophobic compounds achieving better separations faster than before. As the carbon load of Inertsil ODS-SP is relatively low, it is compatible with 100 % aqueous eluents and offer faster equilibration of column for gradient analysis.
Inertsil ODS-3V offers all of the outstanding chromatographic benefits of Inertsil ODS-3 with the added benefit of a more thoroughly documented, validated QC procedure consistent with the demands of GLP/GMP compliance. Each Inertsil ODS-3V is delivered with a Manufacturer‘s Validation Certificate showing the detailed results of every QA and QC step in manufacturing.
The ...
Inertsil Ph has phenethyl groups bonded to silica gel which offers weak pi-pi interactions. As it is modified with phenethyl groups, hydrophobic interactions between alkyl chain and analytes play an important role in separation as well as π-π interactions. To change the selectivity or elution pattern drastically, InertSustain Phenyl is recommended as it provides strong pi-pi ...
Inertsil NH2 amino column shows far superior stability compared to other brand available aminopropyl columns, as our newly developed "Evolved Surface Silica" is chemically bonded with aminopropyl group. Generally, aminopropyl columns are used for applications that are hard to be separated in a reversed phase mode, such as simultaneous analysis of sugars or vitamin E. However, ...
HILIC is, abbreviated name for Hydrophilic Interaction Chromatography, and it was developed as an alternative to reversed phase chromatography for highly polar compounds. Inertsil HILIC is the column which chemically bonded with diol group, and it provides excellent peak shape for neutral and basic compounds. In HILIC mode, generally when organic solvent concentration is ...
Inertsil Amide column is bonded of carbamoyl group, and it shows strong retention of highly polar compounds. As shown below, compared to other commercial columns, Inertsil Amide column showed high retentivity. Inertsil Amide column provides excellent performance for those hard to retain compounds using an ODS column with a long lifetime.
Inertsil Diol column has characteristics of dihydroxypropyl group bonded phase. It shows unique selectivity normal phase mode. The separation mechanism of diol column is featured by hydrogen bonding interactions between diol groups and polar compounds. Diol columns provide an alternative selectivity to silica columns often with increased retentivity. Selectivities of Inertsil ...
Inertsil SIL-100A is a pure silica gel column available in normal phase mode. Because of the high quality of its silica gel, Inertsil SIL-100A achievs separation with sharp peaks and provides high column-to-column reproducibility. This excellent silica gel ideally designed for HPLC is the basis for “Inertsil 3-series” of GL Scineces. GL Sciences is the first company which ...
Inertsil SIL-150A is ultra pure silica gel column, and this ultra pure silica gel contains very low level of metal impurities and is durable and free from dents and cracks which can cause premature column failure. Compared to Inertsil SIL-100A, the silica’s surface area is smaller (320 m²/ g). Retentivity of Inertsil SIL-150A is weaker than that of Inertsil SIL-100A.
Inertsil ODS-4 columns have proven superior worldwide for analysis of strong pharmaceutical bases, acids, chelating compounds, and zwitterions. The long-awaited validated Inertsil ODS-4V has now been added to our product lineup.
Each Inertsil ODS-4V is delivered with a Manufacturer’s Validation Certificate showing the detailed results of every QA and QC step in manufacturing. ...
Inertsil ODS columns are general purpose, reversed phase C18 columns available in 5 μm and 10 μm particle sizes. It was the first ODS bonded phase introduced from GL Sciences back in 1986.
We recommend InertSustain C18 or Inertsil ODS-4 columns for all new method development.
Inertsil WP300 C18 (wide pore size of 300 Å) columns bring the same legendary performance of Inertsil's narrow-pore HPLC products to columns designed specifically for the reproducible separations of proteins and peptides. The results of GL Sciences’ original end-capping technique provide high efficiency and good peak shape for proteins and peptides.
Inertsil WP300 C8 (wide pore size of 300 Å) columns bring the same legendary performance of Inertsil's narrow-pore HPLC products to columns designed specifically for the reproducible rapid separations of proteins and peptides. Inertsil WP300 C8 delivers rapid analysis with sharper peaks compared to Inertsil WP300 C18.
Inertsil WP300 C4 is a butyl group bonded phase utilizing silica gel with wide pores (300 Å). Also, an optimal polar group is embedded between silica surface and butyl group, which reduces adsorption of basic compounds and fat-soluble proteins. Inertsil WP300 C4 is recommended for the analysis of large, highly fat-soluble proteins and peptides.
Inertsil WP300 Diol has dihydroxypropyl group bonded to silica gel with pore size 300 Å and is capable of analyzing large molecules. Like Inertsil Diol, Inertsil WP300 Diol can be used for both aqueous SEC (Size Exclusion Chromatography) and organic SEC. Also, as a diol column, Inertsil WP300 Diol can be used in both normal phase and reversed phase mode.
As the pore size of ...
Inertsil WP300 SIL is pure silica gel phase with wide pores(300 Å). It is available for analysing compounds including large molecules. As the pore becomes wider, the surface area of silica gel is smaller. Since the interactions between the analyte and silica gel occur on the sIlica surface, smaller surface area means less interactions and faster elution. In the figure below, ...
Inertsil C8 columns have a pore size of 150 Å and it is recommended for rapid analysis of highly hydrophobic compounds. We recommend InertSustain C8 or Inertsil C8-4 columns for all new method development.
Inertsil AX has diethylamino groups bonded to silica gel by an alkyl chain. The diethylamino groups offer anionic functions required for anion exchange chromatography. It is mainly used for analyses of acidic compounds. Conventional ion-exchange columns used to show inconsistent results from lot to lot. However, Inertsil AX is manufactured under strict quality control in order ...
The Inertsil CX Cation Exchange HPLC Column has benzenesulfonyl groups bonded to silica gel by an alkyl chain. The sulfonyl groups at the end of the structure offer cationic functions required for the cation exchange chromatography. It is mainly used for analyses of basic compounds. Inertsil CX is manufactured under strict quality control in order to offer excellent batch to ...
Ultra High Retentivity Ideal for Separation of Basic Molecules & its Related Substances, Process Impurities
Inertsil ODS-HL employs a highly inert packing material which provides pure hydrophobic interaction between analytes without generating any secondary interaction delivering sharp peaks. High-Density bonding of C18 phase delivers alternative selectivity to conventional ...
High inertness — Inertsil columns feature sophisticated surface treatment to provide exceptionally low interference of analyte by surface silanols
Extremely low operating back pressure — new surface silica technology allows for the production of particles with a high degree of uniform size, shape, and distribution which vastly lowers the operating back pressure, allowing for long column service life
High reproducibility — produced exclusively in GL Sciences' in-house facilities with a high level of quality control, Inertsil columns are guaranteed to provide excellent reproducibility of results from lot-to-lot