Mobile Phase Cleaner

Eliminate ghost peaks. Protect columns. Stabilize baselines.

Mobile Phase Cleaner is an in-line mobile-phase cleanup cartridge packed with high-purity activated carbon beads. Installed between the pump outlet and injector inlet, it captures trace organic contaminants from solvents, reagents/additives, and upstream LC components before they reach the injector, analytical column, or detector.

Because the cleaner is positioned before the injector, the injected sample does not pass through the sorbent. This allows the mobile phase to be cleaned without directly interacting with sample analytes.

By reducing mobile-phase-derived background, Mobile Phase Cleaner improves baseline stability, increases S/N ratio, and helps enable lower LOD/LOQ in trace-level analysis. High-pressure formats up to 120 MPa make it suitable for HPLC, UHPLC, and LC-MS workflows.

Key Benefits

  • Cleaner baselines: Reduces ghost peaks and background originating from the mobile phase.
  • Higher S/N: Lowers chemical background that can obscure low-level analytes.
  • Trace analysis: Improved baseline stability supports more sensitive quantitation.
  • Column protection: Reduces contaminant loading before the injector and analytical column.
  • LC-MS ready: Designed for workflows where mobile-phase background limits sensitivity.
More about Mobile Phase Cleaner

Specifications

Column format: Cartridge
Length: 20 mm, 30 mm, 50 mm, 75 mm
Inner diameter: 2.1 mm, 3.0 mm, 4.0 mm, 4.6 mm, 7.6 mm
Max Pressure: 120 MPa (1,200 bar), 60 MPa (600 bar), 20 MPa (200 bar)
Base gel: Active Carbon
Certificate of Analysis included with every analytical column
Get Expert Advice or a Fast Quote
*
*
*
By clicking Send, you agree to our Privacy Policy & Terms of Service
GL Sciences: Trusted by Scientists Since 1968

About Mobile Phase Cleaner

Reduction of Mobile-Phase-Derived Ghost Peaks

Blank gradient chromatograms obtained with distilled water and acetonitrile as the mobile phases. Trace mobile-phase contaminants can accumulate on the analytical column during equilibration and elute as ghost peaks as the organic strength increases. Installing Mobile Phase Cleaner upstream of the injector substantially reduced these peaks, demonstrating effective removal of mobile-phase-derived organic contaminants.

The Mobile Phase Cleaner effectively removes UV-absorbing impurities derived from mobile phases, resulting in a cleaner baseline and reduced ghost peaks.

Without Mobile Phase Cleaner

Reduction of Mobile-Phase-Derived Ghost Peaks. Without Mobile Phase Cleaner
 

With Mobile Phase Cleaner

Reduction of Mobile-Phase-Derived Ghost Peaks. With Mobile Phase Cleaner
 

Conditions

ColumnInertSustain AQ-C18, 3 µm, 100 × 3.0 mm I.D.
Mobile phaseA = Acetonitrile / B = Water
Gradient programA = 0% (0 min) – 100% (30 min)
Flow rate0.6 mL/min
Column temperature40 °C
DetectionUV 210 nm

Diclofenac Sodium Analysis

The Mobile Phase Cleaner removes interfering peaks, enabling more accurate quantification of diclofenac sodium.

Without Mobile Phase Cleaner

Diclofenac Sodium Analysis. Without Mobile Phase Cleaner. Diclofenac Sodium 8.549 min, Interfering peak 14.425 min

UV 280 nm

With Mobile Phase Cleaner

Diclofenac Sodium Analysis. With Mobile Phase Cleaner. Diclofenac Sodium 9.176 min

UV 280 nm

Comparison of diclofenac sodium analysis with and without Mobile Phase Cleaner

An interfering peak observed without Mobile Phase Cleaner is effectively removed after installation, resulting in a cleaner baseline and improved analytical reliability.

HPLC Flow Path and Installation Position

Mobile Phase Cleaner is installed in-line between the pump outlet and injector inlet to remove trace organic contaminants before they enter the injector and analytical column.

HPLC Flow Path and Installation Position

Accessories

DescriptionsO.D.I.D.LengthMax. Press.Cat. No.
Precut SS Tubing1/16"0.13 mm50 mm>173.5 MPa
(>25,160 psi)
6010-33001
100 mm6010-33002
200 mm6010-33003
0.25 mm50 mm6010-33010
100 mm6010-33020
200 mm6010-33030
Finger-Tight High-Pressure FittingThumb Nut + Reusable Ferrule
10 sets
50 MPa6010-77080
UHPLC High-Pressure Fitting SetNut + Reusable Ferrule
10 sets
140 MPa
(20,300 psi)
6010-77082
There are application notes for Mobile Phase Cleaner.